Gas-analyzer, spectrometers

Gas analyzer, spectrometers

Gas analyzer "ELTRA" ОН900

Gas analyzer "ELTRA" ОН900 (GmbH ELTRA, Germany) is used to define the content of hydrogen and oxygen in zirconium, titanium, hafnium, aluminum, copper, steels and alloys, ceramics and other materials. The range of H and O content measurement makes up 0.0001 – 5.0 % (mass fraction).




Spectrometer "Spectroflame Modula S"

Emission plasma spectrometer "Spectroflame Modula S" (Germany) is used for quantitative analysis of water solutions of various materials (more than 70 elements). Scanning field-emission spectrometer with inductive coupled plasma "Spectroflame Modula S" is equipped with two monochromators: vacuum (160-460nm, reverse dispersion 0.55nm/mm) and air (240-790nm, reverse dispersion 1.1nm/mm). It allows identification of up to 70 elements in the material, the spectrum range being wide.

Mass-spectrometer MS-7202M

Secondary-ion mass-spectrometer ion probe MS-7202M (“SELMI”, Ltd., Ukraine): registration of all elements, isotopes and compounds in the mass number range 1-250 and1-500 after adjustment; high sensitivity for some elements (up to 10-16 atom/g); images can be done both in secondary ions and absorbed current; profile of elements distribution can be defined; compensating electron bombardment can be used when working with non-conductive samples; operating vacuum is 5x10-6 Pa. Primary ions source - duoplasmatron using argon and oxygen. The minimal diameter of an ion beam - 10mkm. Accelerating voltage – 10keV.

Auger-electron spectrometer ESO-5UM

Scanning Auger-electron spectrometer ESO-5UM (“Burevestnik”, Russia): registration of all elements with numbers higher than helium; high sensitivity to light elements (Z-7 - 3x10-8 Pa; operating gas for ion guns – argon; maximal size of scanning pattern in Auger-electrons – 0.3*0.3mm. Maximal accelerating voltage of ion gun and voltage of ion and electron guns – 10kV; minimal diameter of ion beam – 0.01mm.

Mass-spectrometer TRITON

Thermo-ionizing Mass-spectrometer TRITON (Finnigan MAT, Germany): isotopic sensitivity - 2x10-6 at a mass of 273 for uranium; maximal magnetic field value – 1.2T (12000Gs) in the mass range from 1 to 340; D to A converter with an alternate focus distance; resolution capacity in mass – up to 0.000025a.m.u.; range of measured isotopes content – from 0 to100%; level of noise signal - 10-5 V; a multi-collector receiver with variable position of collectors to measure up to 9 various isotopes at a time; operating vacuum in the ion beam - -7 bar; operating vacuum in the analyzer chamber - -9 bar.